| DISPLAY TYPE | POWER MEASUREMENT | AUXILIARY POWER SUPPLY | |||
| LCD display | Real power, apparent power, reactive power measurement | AC voltage | : 90 ~ 415 V AC | ||
| MEASUREMENTS | Measuring updating period | : 1 s | Frequency | : 50 / 60 Hz | |
| 3-phase 4-wire system | Accuracy | : 1.0% | DC voltage | : 100 ~ 300 V DC | |
| 3-phase 3-wire system | POWER DEMAND | Power consumption | : <3 VA | ||
| CURRENT MEASUREMENT (TRMS) | Interval | : 1 ~ 30 Phút | |||
| CT primary | : 5 ~ 9995 A | POWER FACTOR MEASUREMENT | |||
| CT secondary | : 5 A | Total and displacement power factor |
|||
| Minimum measurement | : 5 mA | Accuracy | : 1.0% | ||
| Accuracy | 0.5% từ 1A đến 6A ( Thứ cấp) | FREQUENCY MEASUREMENT | ENVIRONMETAL CONDITIONS | ||
| Burden | : < 0.05 VA tại 5 A | Measurement range | : 45 ~ 65 Hz | Temperature | : -10°C to 55°C |
| Sustained overload | : 6 A | Measurement updating period | : 1s | Humidity | : 5% đến 95%, non-condensing |
| VOLTAGE MEASUREMENT (TRMS) | Accuracy | : 0.5% | MECHANICAL | ||
| Nominal phase voltage | : 20 ~ 300 V AC | ENERGY ACCURACY | Mounting | : Panel mounting | |
| Minimum measurement | :10 V | Active (according to IEC 62053-21) | : class 1 | Dimension (mm) | : 96(w) x 96(h) x 87.5(d) |
| Accuracy | 0.5% | Reactive (according to IEC 62053-23) | : class 2 | Approximate weight | : 0.40kg |
| Phase voltage via VT | : 60 ~ 33,000 V | Enclosure protection | : IP54 at the pane , IP20 at the body | ||
| 3-PHASE 4-WIRE SYSTEM: 4CTs, DIRECT INPUT VOLTAGE | 3-PHASE 4-WIRE SYSTEM: 3CTs, DIRECT INPUT VOLTAGE | 3-PHASE 3-WIRE SYSTEM: 3CTs, 3VTs | 3-PHASE 3-WIRE SYSTEM: 2CTs, 2VTs |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Power supply voltage: 90-415VAC or 100-300VDC, RS485 communication |
| View from the front | View from behind | Cabinet cut-out size | MODEL: RX380-415AD |
Our company assembles and installs power monitoring systems for factories, buildings, hospitals, schools, and production and business establishments.
| POWER FACTOR REGULATOR | Earth Leakage System | Reverse Power Relay |
| DIGITAL POWER METER | Overcurrent Relays | Annunciator |
| EARTH LEAKAGE RELAYS | Voltage Relays | Motor Protection Relay |
| Capacitor | Reactor | OVERCURRENT & EARTH FAULT RELAYS |
Specific References