By continuing use this site, you agree to the Terms & Conditions and our use of cookies.
Power Factor Regulator Mikro PFR80-415-50 Used for 3P 380V/50HZ power grid
  • Online only
  • On sale!
  • -₫500,000.00
  • New
Review (0)
00
day
:
00
hour
:
00
min
:
00
sec
₫3,480,000.00₫3,980,000.00
Power Factor Regulator Mikro  PFR96-110-60
  • Online only
  • On sale!
  • -₫500,000.00
  • New
Review (0)
00
day
:
00
hour
:
00
min
:
00
sec
₫3,070,000.00₫3,570,000.00
Power Factor Regulator Mikro  PFR96-110-50
  • Online only
  • On sale!
  • -₫500,000.00
  • New
Review (0)
00
day
:
00
hour
:
00
min
:
00
sec
₫3,070,000.00₫3,570,000.00
Power Factor Regulator Mikro PFR96P-415-60
  • Online only
  • On sale!
  • -₫500,000.00
  • New
Review (0)
00
day
:
00
hour
:
00
min
:
00
sec
₫3,070,000.00₫3,570,000.00
Power Factor Regulator Mikro PFR96P-415-50
  • Online only
  • On sale!
  • -₫500,000.00
  • New
Review (0)
00
day
:
00
hour
:
00
min
:
00
sec
₫3,070,000.00₫3,570,000.00
  • Online only
  • New
  • On sale!
Mikro DPM380-415AD DIGITAL POWER METER MODBUS-RTU communication size 96mmx96mm
Mikro DPM380-415AD DIGITAL POWER METER MODBUS-RTU communication size 96mmx96mm

Mikro DPM380-415AD DIGITAL POWER METER MODBUS-RTU communication size 96mmx96mm

Review (0)
₫4,265,800.00
₫6,094,000.00
Save 30%
( Tax Included VAT 10% )
Order products 4-6 weeks in advance
  • • Phase Voltage (L-N) & Line Voltage (L-L)
  • • Min & Max Phase and Line Voltage
  • • Phase Current and Neutral Current
  • • Min & Max Phase Current and Neutral Current
  • • Bidirectional kW (per phase & total)
  • • Bidirectional kVAR (per phase & total)
  • • kVA (per phase & total) • Min & Max kW, kVAR and KVA
  • • Frequency
  • • True & Displacement Power Factor (per phase & total)
  • • Energy kWh, kVARh and kVAh
  • • THD Phase Voltage ( L-N )
  • • THD Phase Current
  • • Power Demand (kW, kVAR & kVA)
  • • Maximum Power Demand (kW, kVAR & kVA)
00
day
:
00
hour
:
00
min
:
00
sec
Quantity :
No Product available
Write your review
EU3234363840424446USXX5XSSMLXLXXLXXLArm Length6161,56262,56363,56464,5Bust Circumference8084889296101106111Waist Girth6165697377828792Hip Circumference87919599103108113118
  • Phone: 0939215809Phone: 0939215809
  • Skype: thaidainamSkype: thaidainam
  • Email: diendainam@gmail.comEmail: diendainam@gmail.com

TECHNICAL SPECIFICATIONS OF POWER MONITORING METER Mikro DPM380-415AD

DISPLAY TYPE POWER MEASUREMENT AUXILIARY POWER SUPPLY
LCD display Real power, apparent power, reactive power measurement AC voltage : 90 ~ 415 V AC
MEASUREMENTS Measuring updating period : 1 s Frequency : 50 / 60 Hz
3-phase 4-wire system Accuracy : 1.0% DC voltage : 100 ~ 300 V DC
3-phase 3-wire system POWER DEMAND  Power consumption : <3 VA
CURRENT MEASUREMENT (TRMS)  Interval : 1 ~ 30 Phút COMMUNICATION
CT primary : 5 ~ 9995 A POWER FACTOR MEASUREMENT  Hardware interface : Isolated RS485
CT secondary : 5 A Total and displacement power factor

Protoco : Modbus-RTU
Minimum measurement : 5 mA Accuracy : 1.0% Baud rate : 4800, 9600, 19200, 38400
Accuracy 0.5% từ  1A đến 6A ( Thứ cấp) FREQUENCY MEASUREMENT  ENVIRONMETAL CONDITIONS 
Burden : < 0.05 VA tại 5 A Measurement range : 45 ~ 65 Hz Temperature : -10°C to 55°C
Sustained overload : 6 A Measurement updating period  : 1s Humidity : 5% đến 95%, non-condensing
VOLTAGE MEASUREMENT (TRMS)  Accuracy : 0.5% MECHANICAL
Nominal phase voltage : 20 ~ 300 V AC ENERGY ACCURACY  Mounting : Panel mounting
Minimum measurement :10 V Active (according to IEC 62053-21) : class 1 Dimension (mm) : 96(w) x 96(h) x 87.5(d)
Accuracy 0.5%  Reactive (according to IEC 62053-23) : class 2 Approximate weight : 0.40kg
Phase voltage via VT : 60 ~ 33,000 V Enclosure protection : IP54 at the pane , IP20 at the body

WIRING DIAGRAM OF POWER MONITORING METER Mikro DPM380-415AD

3-PHASE 4-WIRE SYSTEM: 4CTs, DIRECT INPUT VOLTAGE 3-PHASE 4-WIRE SYSTEM: 3CTs, DIRECT INPUT VOLTAGE 3-PHASE 3-WIRE SYSTEM: 3CTs, 3VTs 3-PHASE 3-WIRE SYSTEM: 2CTs, 2VTs
so-do-dau-day-mikro-RX380/so-do-dau-day-dong-ho-dien-mikro-RX380-4-day-ap-truc-tiep so-do-dau-day-dong-ho-dien-mikro-RX380-4-day-ap-truc-tiep-3CT so-do-dau-day-dong-ho-dien-mikro-RX380-3-day-ap-gian-tiep-3ct so-do-dau-day-dong-ho-dien-mikro-RX380-3-day-ap-gian-tiep-2ct

INSTALLATION SIZE OF POWER MONITORING METER Mikro DPM380-415AD

kich-thuoc-mikro-MX380-01 kich-thuoc-mikro-MX380-02 kich-thuoc-mikro-MX380-03 Power supply voltage: 90-415VAC or 100-300VDC, RS485 communication
View from the front View from behind Cabinet cut-out size MODEL: RX380-415AD

TECHNICAL SERVICES POWER MONITORING METER Mikro DPM380-415AD

Our company assembles and installs power monitoring systems for factories, buildings, hospitals, schools, and production and business establishments.

PRODUCT LIST

POWER FACTOR REGULATOR Earth Leakage System Reverse Power Relay
DIGITAL POWER METER Overcurrent Relays Annunciator
EARTH LEAKAGE RELAYS Voltage Relays Motor Protection Relay
Capacitor Reactor OVERCURRENT & EARTH FAULT RELAYS

Mikro RX380-415AD

Specific References

No customer reviews for the moment.

Write your review
Mikro DPM380-415AD DIGITAL POWER METER MODBUS-RTU communication size 96mmx96mm
Mikro DPM380 DIGITAL POWER METER

Mikro DPM380-415AD DIGITAL POWER METER MODBUS-RTU communication size 96mmx96mm

₫4,265,800.00
₫6,094,000.00
Save 30%
( Tax Included VAT 10% )
Order products 4-6 weeks in advance