By continuing use this site, you agree to the Terms & Conditions and our use of cookies.
Power Factor Regulator Mikro PFR80-415-50 Used for 3P 380V/50HZ power grid
  • Online only
  • On sale!
  • -₫500,000.00
  • New
Review (0)
00
day
:
00
hour
:
00
min
:
00
sec
₫3,480,000.00₫3,980,000.00
Power Factor Regulator Mikro  PFR96-110-60
  • Online only
  • On sale!
  • -₫500,000.00
  • New
Review (0)
00
day
:
00
hour
:
00
min
:
00
sec
₫3,070,000.00₫3,570,000.00
Power Factor Regulator Mikro  PFR96-110-50
  • Online only
  • On sale!
  • -₫500,000.00
  • New
Review (0)
00
day
:
00
hour
:
00
min
:
00
sec
₫3,070,000.00₫3,570,000.00
Power Factor Regulator Mikro PFR96P-415-60
  • Online only
  • On sale!
  • -₫500,000.00
  • New
Review (0)
00
day
:
00
hour
:
00
min
:
00
sec
₫3,070,000.00₫3,570,000.00
Power Factor Regulator Mikro PFR96P-415-50
  • Online only
  • On sale!
  • -₫500,000.00
  • New
Review (0)
00
day
:
00
hour
:
00
min
:
00
sec
₫3,070,000.00₫3,570,000.00
  • Online only
  • New
  • On sale!
Mikro DPM680-415AD DIGITAL POWER METER TFT LCD color screen
Mikro DPM680-415AD DIGITAL POWER METER TFT LCD color screen

Mikro DPM680-415AD DIGITAL POWER METER TFT LCD color screen

Review (0)
₫9,317,000.00
₫13,310,000.00
Save 30%
( Tax Included VAT 10% )
Delivery within 24 working hours
Last items in stock
  • - Communication via MODBUS TCP/IP or RS-485 MODBUS-RTU communication
  • - Measure and display voltage (L-N) and line voltage (L-L).
  • - Measure and display current on phase and current on neutral wire.
  • - Carry out KW work (in stages & synthesis).
  • - Measure KVAR reflected power (on each phase & total).
  • - Measure the KVA symbol (on phase & total).
  • - Measure and display frequency. Measure and display COSφ work system (by phase &
  • synthetic).
  • - Measure electricity (+ and -) for kWh, kVARh and kVAh.
  • - Measure and display applied electrical THD harmonics and current (% or table format).
  • - Use for Middle/Low voltage systems
  • - Meets IEC 61010-1, IEC 61326-1 standards.
  • - Dimensions (h x w x d): 96 x 96 x 83mm.
00
day
:
00
hour
:
00
min
:
00
sec
Quantity :
Hurry Up Only 1 Items left items
Write your review
EU3234363840424446USXX5XSSMLXLXXLXXLArm Length6161,56262,56363,56464,5Bust Circumference8084889296101106111Waist Girth6165697377828792Hip Circumference87919599103108113118
  • Phone: 0939215809Phone: 0939215809
  • Skype: thaidainamSkype: thaidainam
  • Email: diendainam@gmail.comEmail: diendainam@gmail.com

TECHNICAL SPECIFICATIONS OF POWER MONITORING METER Mikro DPM380B-415AD

DISPLAY TYPE POWER MEASUREMENT AUXILIARY POWER SUPPLY
LCD display Real power, apparent power, reactive power measurement AC voltage : 90 ~ 415 V AC
MEASUREMENTS Measuring updating period : 1 s Frequency : 50 / 60 Hz
3-phase 4-wire system Accuracy : 1.0% DC voltage : 100 ~ 300 V DC
3-phase 3-wire system POWER DEMAND  Power consumption : <3 VA
CURRENT MEASUREMENT (TRMS)  Interval : 1 ~ 30 Phút
CT primary : 5 ~ 9995 A POWER FACTOR MEASUREMENT 
CT secondary : 5 A Total and displacement power factor

Minimum measurement : 5 mA Accuracy : 1.0%
Accuracy 0.5% từ  1A đến 6A ( Thứ cấp) FREQUENCY MEASUREMENT  ENVIRONMETAL CONDITIONS 
Burden : < 0.05 VA tại 5 A Measurement range : 45 ~ 65 Hz Temperature : -10°C to 55°C
Sustained overload : 6 A Measurement updating period  : 1s Humidity : 5% đến 95%, non-condensing
VOLTAGE MEASUREMENT (TRMS)  Accuracy : 0.5% MECHANICAL
Nominal phase voltage : 20 ~ 300 V AC ENERGY ACCURACY  Mounting : Panel mounting
Minimum measurement :10 V Active (according to IEC 62053-21) : class 1 Dimension (mm) : 96(w) x 96(h) x 87.5(d)
Accuracy 0.5%  Reactive (according to IEC 62053-23) : class 2 Approximate weight : 0.40kg
Phase voltage via VT : 60 ~ 33,000 V Enclosure protection : IP54 at the pane , IP20 at the body

WIRING DIAGRAM OF POWER MONITORING METER Mikro DPM380B-415AD

3-PHASE 4-WIRE SYSTEM: 4CTs, DIRECT INPUT VOLTAGE 3-PHASE 4-WIRE SYSTEM: 3CTs, DIRECT INPUT VOLTAGE 3-PHASE 3-WIRE SYSTEM: 3CTs, 3VTs 3-PHASE 3-WIRE SYSTEM: 2CTs, 2VTs
so-do-dau-day-mikro-RX380/so-do-dau-day-dong-ho-dien-mikro-RX380-4-day-ap-truc-tiep so-do-dau-day-dong-ho-dien-mikro-RX380-4-day-ap-truc-tiep-3CT so-do-dau-day-dong-ho-dien-mikro-RX380-3-day-ap-gian-tiep-3ct so-do-dau-day-dong-ho-dien-mikro-RX380-3-day-ap-gian-tiep-2ct

INSTALLATION SIZE OF POWER MONITORING METER Mikro DPM380B-415AD

kich-thuoc-mikro-MX380-01 kich-thuoc-mikro-MX380-02 kich-thuoc-mikro-MX380-03 Power supply voltage: 90-415VAC or 100-300VDC, RS485 communication
View from the front View from behind Cabinet cut-out size MODEL: RX380-415AD

TECHNICAL SERVICES POWER MONITORING METER Mikro DPM380B-415AD

Our company assembles and installs power monitoring systems for factories, buildings, hospitals, schools, and production and business establishments.

PRODUCT LIST

POWER FACTOR REGULATOR Earth Leakage System Reverse Power Relay
DIGITAL POWER METER Overcurrent Relays Annunciator
EARTH LEAKAGE RELAYS Voltage Relays Motor Protection Relay
Capacitor Reactor OVERCURRENT & EARTH FAULT RELAYS

MiKro
Mikro DPM380B-415AD
1 Item

Specific References

No customer reviews for the moment.

Write your review
Mikro DPM680-415AD DIGITAL POWER METER TFT LCD color screen
Mikro DPM680-415AD DIGITAL POWER METER

Mikro DPM680-415AD DIGITAL POWER METER TFT LCD color screen

₫9,317,000.00
₫13,310,000.00
Save 30%
( Tax Included VAT 10% )
Delivery within 24 working hours