- Online only
- New
- On sale!
![Power Factor Regulator Mikro PFR120-415-50 Used for 3P 380V/50HZ power grid Power Factor Regulator Mikro PFR120-415-50 Used for 3P 380V/50HZ power grid](https://thietbidainam.vn/1047-large_default/power-factor-regulator-mikro-pfr120-415-50-used-for-3p-380v50hz-power-grid.jpg)
![Power Factor Regulator Mikro PFR120-415-50 Used for 3P 380V/50HZ power grid Power Factor Regulator Mikro PFR120-415-50 Used for 3P 380V/50HZ power grid](https://thietbidainam.vn/1047-side_product_default/power-factor-regulator-mikro-pfr120-415-50-used-for-3p-380v50hz-power-grid.jpg)
Established in 2009. Reputable website providing equipment supplies and factory technical solutions. Zalo: 0939215809
MODEL | DESCRIPTION | MODEL | DESCRIPTION |
Frequency 50HZ | |||
PFR60-415-50 |
6 Steps, 50 Hz system, auxiliary voltage 380~415 V AC
|
PFR60-220-50 |
6 Steps, 50 Hz system, auxiliary voltage 220~240 V AC
|
PFR80-415-50 |
8 Steps, 50 Hz system, auxiliary voltage 380~415 V AC
|
PFR80-220-50 |
8 Steps, 50 Hz system, auxiliary voltage 220~240 V AC
|
PFR120-415-50 |
12 Steps, 50 Hz system, auxiliary voltage 380~415 V AC
|
PFR120-220-50 |
12 Steps, 50 Hz system, auxiliary voltage 220~240 V AC
|
PFR140-415-50 |
14 Steps, 50 Hz system, auxiliary voltage 380~415 V AC
|
PFR140-220-50 |
14 Steps, 50 Hz system, auxiliary voltage 220~240 V AC
|
Frequency 60HZ | |||
PFR60-415-60 |
6 Steps, 60 Hz system, auxiliary voltage 380~415 V AC
|
PFR60-220-60 |
6 Steps, 60 Hz system, auxiliary voltage 220~240 V AC
|
PFR80-415-60 |
8 Steps, 60 Hz system, auxiliary voltage 380~415 V AC
|
PFR80-220-60 |
8 Steps, 60 Hz system, auxiliary voltage 220~240 V AC
|
PFR120-415-60 |
12 Steps, 60 Hz system, auxiliary voltage 380~415 V AC
|
PFR120-220-60 |
12 Steps, 60 Hz system, auxiliary voltage 220~240 V AC
|
PFR140-415-60 |
14 Steps, 60 Hz system, auxiliary voltage 380~415 V AC
|
PFR140-220-60 |
14 Steps, 60 Hz system, auxiliary voltage 220~240 V AC
|
Note: For the power grid in Vietnam, use the 3P power grid system, 380V to 415V, frequency is 50HZ, these products are often available, the remaining 3P power grid, 220V to 240V, frequency 60HZ is usually available. must order.
![]() |
![]() |
Our company provides reactive power compensation cabinet installation services upon request. Construction according to pre-designed drawings, or consulting on compensation capacity, actual compensation solutions for each customer. Depending on the actual measurement, choose a reasonable reactive power compensation solution to avoid being fined.
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
System voltage | 380V, 400V, 415V, etc. |
Working frequency (HZ) | 50Hz/60Hz |
Compensation capacity response | 10kvar~1200kvar |
Capacitor voltage | 250VAC~690VAC |
Working temperature of capacitor | -25℃~+55℃ |
Control voltage | AC220V, DC110V, etc. |
Control mode | Manual/automatic |
Voltage protection | 255V±5% |
Overcurrent protection | Set according to rated capacity |
Short circuit protection | 100kA |
Insulating materials | ≥100MΩ |
Protection level | IP30~IP54 |
Size | Customizable according to actual size and compensation capacity |
Data sheet
Specific References
No customer reviews for the moment.